Relative humidity (RH) is the ratio, usually expressed as a percentage, between the actual partial pressure of water vapour in air and the saturation vapour pressure at the same temperature.[1][2] In a sauna, the value can differ by position and change quickly after water is cast on heated stones. A useful reading therefore requires its temperature, location and time or averaging period.

RH is one variable within the Sauna climate, rather than a complete description of the room. It does not by itself measure vapour mass, ventilation, heat received by a bather, comfort or safety. Its role in Sauna technology is chiefly to describe and monitor one aspect of the local moist-air state.

Definition and related quantities

The reference saturation pressure is temperature-dependent. Thirty per cent RH means that the actual water-vapour pressure is 30 per cent of the relevant saturation value; it does not mean that 30 per cent of the air is water. RH has no physical unit, although it is conventionally reported with a percent sign. A change from 20 to 30 per cent RH is an increase of ten percentage points.

Other humidity quantities describe different properties. Absolute humidity is water-vapour mass per unit volume, while humidity ratio is the mass of vapour per unit mass of dry air and specific humidity is a mass fraction of moist air. ASHRAE distinguishes all three, although some sauna publications call a value in grams per kilogram “absolute humidity” even though the unit denotes a mass ratio.[1] Dew point is the temperature at which a sample would become saturated if cooled at the relevant pressure without first gaining or losing vapour. It represents the existing vapour state differently from RH, but is not itself a measure of total heat or moisture transfer.[2]

Line chart of saturation vapour pressure of water from 0 to 100 degrees Celsius with a horizontal dashed line and three marked points at 40, 60 and 80 degrees.
Saturation vapour pressure of water rises steeply with temperature. Along the dashed line the vapour pressure is the same, so the relative humidity falls as the air is heated; equal RH readings at different temperatures therefore represent different vapour contents. Calculated example, not a sauna measurement.

If moist air is heated while its composition and total pressure remain effectively unchanged, its saturation pressure rises and its RH falls. Cooling produces the converse until saturation is reached and condensation can alter the amount of vapour. Equal RH readings at different air temperatures can consequently represent different vapour contents. Local condensation is also possible while a room sensor reads below 100 per cent RH: a cooler surface can lie below the dew point of the adjacent air even though the warmer measuring point is unsaturated.

Spatial and temporal variation

A sauna does not have a single uniform RH. Temperature gradients, water casting and imperfect mixing create local values, while air movement transports both heat and vapour. Ventilation can supply, remove or redistribute moisture, but an RH reading alone cannot determine an air-change rate. VTT experiments in mechanically extracted test rooms found that inlet and outlet placement and the resulting mixing affected the vertical climate and the distribution of humidity during water casting.[3] Those rooms and ventilation arrangements do not establish a universal gradient.

Two small charts comparing 0.90 metres and 1.73 metres: temperature is higher at the upper height and relative humidity is higher at the lower height, each with error bars.
Mean temperature and relative humidity at two heights in one 2026 study (minutes 2-10 of four ten-minute rounds, 50 participants, four saunas). Bars show one standard deviation. The figures describe that protocol, not preferred conditions. Data: Laatikainen-Raussi et al. 2026, CC BY 4.0.

Multi-point measurements published in 2026 illustrate why height matters. Fifty analysed healthy, recreationally active adults completed four ten-minute sauna rounds and could cast water after the first two minutes. Across minutes 2–10, sensors at 0.90 metres averaged 50.8 ± 5.1 °C and 53.8 ± 20.1 per cent RH; sensors at 1.73 metres averaged 69.0 ± 5.5 °C and 27.7 ± 11.7 per cent RH. The mean across all six positions was 59.9 ± 5.8 °C and 40.8 ± 15.4 per cent RH.[4] These figures describe that protocol, not preferred conditions. Temperature probably explains part, but not necessarily all, of the vertical RH difference because vapour distribution can also vary.

The often-quoted range of 10–20 per cent RH comes from a different evidence context. A 2018 systematic review reported 10–20 per cent RH at 80–90 °C for almost all included Finnish-style sauna interventions.[5] Those were selected research protocols, not a representative survey of saunas, and generally did not characterise short moisture pulses at several heights. The review range and the newer field measurements therefore should not be treated as competing universal definitions.

Water casting and surfaces

During löyly, some water applied to sufficiently hot stones vaporises and the vapour-rich flow mixes through the room. RH commonly rises for a limited period, with the recorded peak and duration depending on dose, stone state, position, mixing, surfaces and sensor response.[3][6] The detailed energy and mass balance belongs to Löyly physics. An intermittent addition of water vapour is not the same operating condition as continuous humidification of a whole room.

One experiment deliberately magnified the transient. Researchers sealed the door, closed a ceiling duct and largely covered the heater with aluminium foil for thermography in a single spruce-lined sauna, then applied one, two or three litres of water. RH and wooden-surface temperature responded much more strongly than bulk air temperature.[6] The test demonstrates that a humidity pulse need not produce a comparable rise in air temperature; its large doses and modified enclosure are not ordinary-use instructions.

Hygroscopic surfaces can absorb and later release moisture, so construction and surface temperature affect the transient. In a Helsinki field study of nine shared and public saunas, detailed continuous results concentrated on two rooms. Cooled ceramic seats at about 40–45 °C had continuous condensation, whereas wooden seats at about 60–70 °C had greater drying capability.[7] Because material and surface temperature differed together, the comparison does not isolate either factor.

Measurement and reporting

A wall-mounted Sauna hygrometer supplies a local indication. An electronic Sauna humidity sensor may instead feed a display, logger or control, but neither arrangement guarantees that the occupied zone is represented. For quantitative work, the instrument must tolerate the expected temperature and humidity, and its calibration, hysteresis, drift, response and stabilisation time must suit the measurement. Decimal places indicate resolution, not accuracy.

This distinction is especially important during a short water-casting pulse. A slow sensor can smooth or miss a peak, while a cooler position can indicate higher RH than a warmer position even when their vapour states are similar. National Physical Laboratory guidance treats a representative air temperature as essential to an RH result and recommends repeated readings when conditions cycle.[2] ISO 7726:2025 specifies minimum characteristics of instruments and methods for measuring physical environmental quantities, but its public scope neither validates a consumer hygrometer nor supplies a sauna placement rule.[8]

Calibration requires controlled reference conditions. NIST calibrates thermohygrometers across 2–98 per cent RH at temperatures from −34 to 85 °C in a chamber with controlled temperature and pressure.[9] This describes NIST's service, not the operating range or fitness of a sauna instrument. Reproducible humidity reporting states the humidity quantity and unit, simultaneous temperature, height and horizontal position, timing or averaging window, water-casting and occupancy context, ventilation state, instrument specification and relevant uncertainty.[2][4]

Heat, sensation and interpretation

RH can affect Heat transfer in a sauna, but it does not quantify total heat flow. Evaporation from wet skin depends on a vapour-pressure gradient as well as local air movement and skin wetness; condensation on a cooler surface can transfer latent energy.[4] Convection and thermal radiation remain separate. The same RH can therefore accompany different heat exchange and thermal sensation when temperature, surfaces or air movement differ.

In the 2026 study, temperature and RH were independently associated with immediate heart-rate and core-temperature changes in adjusted statistical models, while temperature made the larger contribution to reported sensation.[4] Humidity was not randomly assigned, water casting was self-selected and the four rooms used different heaters. Harvia supported the research infrastructure and publication costs, and Toyota partly funded the measurements. The results are study-specific associations, not causal increments, comfort equations or exposure limits. Adding degrees Celsius to percentage RH is dimensionally invalid and has no verified role as a universal sauna rule.

A conventional sauna with intermittent water casting differs from a Steam bath maintained as a highly humid room. EN 18164:2026 separately classifies sauna rooms, warm-air rooms, steam rooms and soft-steam rooms within its requirements for climated rooms for public use.[10] That European public-facility scope does not create a worldwide domestic classification. Similarly, a programme label such as Bio sauna does not by itself establish a scientifically universal RH band. In any room type, RH alone cannot establish authenticity, safety, adequate drying, mould risk, ventilation performance or health benefit.

References

  1. ↑ 1.0 1.1 ASHRAE, “Psychrometrics”, chapter 1 in 2017 ASHRAE Handbook—Fundamentals, https://handbook.ashrae.org/Handbooks/F17/SI/f17_ch01/f17_ch01_si.aspx, accessed 4 September 2026.
  2. ↑ 2.0 2.1 2.2 2.3 Stephanie Bell, The Beginner’s Guide to Humidity Measurement, Measurement Good Practice Guide No. 124, National Physical Laboratory, May 2013, ISSN 1368-6550, https://eprintspublications.npl.co.uk/7464/1/mgpg124.pdf, accessed 4 September 2026.
  3. ↑ 3.0 3.1 Erkki Äikäs and Rolf Holmberg, Saunan lämpötilat ja ilmanvaihto [Temperature and ventilation of the Finnish sauna], VTT Research Notes 1431, VTT Technical Research Centre of Finland, Espoo, 1992, 40 pp., ISBN 951-38-4325-4, https://cris.vtt.fi/en/publications/saunan-l%C3%A4mp%C3%B6tilat-ja-ilmanvaihto/, accessed 4 September 2026.
  4. ↑ 4.0 4.1 4.2 4.3 Iida Laatikainen-Raussi, Tom Mikkola, Johanna K. Ihalainen and Essi Ahokas, “Temperature and humidity independently influence thermoregulatory responses during Finnish sauna bathing”, Temperature, published online 11 July 2026. doi:10.1080/23328940.2026.2698162.
  5. ↑ Joy Hussain and Marc Cohen, “Clinical Effects of Regular Dry Sauna Bathing: A Systematic Review”, Evidence-Based Complementary and Alternative Medicine, volume 2018, article 1857413. doi:10.1155/2018/1857413.
  6. ↑ 6.0 6.1 Kristine Nore, Dimitrios Kraniotis and Christoph Brückner, “The Principles of Sauna Physics”, Energy Procedia, volume 78, 2015, pp. 1907–1912. doi:10.1016/j.egypro.2015.11.361.
  7. ↑ Mikko Saari, Marja-Liisa Pallari, Mikael Salonvaara, Hannu Kääriäinen, Hannu Viitanen, Kari Laitinen, Ilkka Humala, Sirkka Liski-Markkanen and Antti Malin, “Healthy Sauna”, in Proceedings: Indoor Air 2002, pp. 394–399, https://www.irbnet.de/daten/iconda/CIB6615.pdf, accessed 4 September 2026.
  8. ↑ International Organization for Standardization, ISO 7726:2025, Ergonomics of the thermal environment — Instruments for measuring and monitoring physical quantities, edition 3, October 2025, https://www.iso.org/standard/78238.html, accessed 4 September 2026.
  9. ↑ National Institute of Standards and Technology, “Hygrometers”, updated 28 November 2022, https://www.nist.gov/pml/sensor-science/thermodynamic-metrology/hygrometers, accessed 4 September 2026.
  10. ↑ European Committee for Standardization, EN 18164:2026, Wellness facilities for public use — Climated rooms — Requirements, approved 26 January 2026, https://normy.normoff.gov.sk/norma/142477/nahlad/, accessed 4 September 2026.

Template:Sauna technology