File:Protective earthing Class I and Class II conceptual diagram.svg
Protective_earthing_Class_I_and_Class_II_conceptual_diagram.svg (SVG file, nominally 2,400 × 1,350 pixels, file size: 5 KB)
Summary
Two panels compare an unarrowed Class I protective-conductor connection with two separately labelled basic and supplementary insulation barriers in a Class II example.
The Class I connection is shown only as a segment continuing outside the view; no fault-current flow is drawn and no current disappears at the boundary. Protective devices, rather than the conductor itself, perform disconnection. The Class II panel specifically depicts double insulation, comprising basic and supplementary insulation. Reinforced insulation instead provides equivalent protective performance as one insulation system, which can have multiple physical layers; it is not a mandatory extra layer over basic insulation. No earthing system, thickness, wiring rule or sauna-wide requirement is selected. Label key: A: Accessible conductive part. B: Installation continues outside view. C: Supplementary insulation. Notes: Protective devices provide disconnection. Reinforced insulation is an alternative, not an extra layer. Class follows documented equipment design; appearance is insufficient.
Source
Made for the RUVARO Sauna Wiki (image plan G05, asset G05-E04). Planned for: Electrical earthing in a sauna. Based on:
- IEC 60364-5-54:2011+AMD1:2021, Earthing arrangements and protective conductors — https://webstore.iec.ch/en/publication/68865
- IEC 61140:2016, Protection against electric shock, Common aspects for installation and equipment — https://webstore.iec.ch/en/publication/23997
- Electrical earthing in a sauna
- GSO IEC 60335-1:2022, official GSO public preview of IEC appliance safety definitions — https://gso-sims-preview-doc-aws.s3-eu-west-1.amazonaws.com/gso-iec-60335-1-2022-en.html
- IEC Electropedia, IEV 851-15-07, source 195-06-09, published 2008-06 — https://electropedia.org/iev/iev.nsf/17127c61f2426ed8c1257cb5003c9bec/497ebfc7321d5bbcc125764d002f7565?OpenDocument=
- IEC 60364-5-54:2011+AMD1:2021, edition 3.1 — https://webstore.iec.ch/en/publication/68865
- Schneider Electric, How does RCD work?, published 14 October 2021, updated 26 August 2025 — https://www.se.com/nz/en/faqs/FAQ000210095/
- Unmodified G05 wiki source cache — https://ruvarowellness.com/wiki/
Production
- Method: vector drawing written as SVG code (svg_code), not a raster image.
- Date: 18 October 2026.
- Status: draft. Pending review: technical review.
Licensing
© 2026 RUVARO. All rights reserved. This image was made for the RUVARO Sauna Wiki and is the property of RUVARO. No licence is granted for use outside this wiki; reproduction, adaptation or distribution requires prior written permission from RUVARO.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 12:12, 18 October 2026 | 2,400 × 1,350 (5 KB) | Nora van Rossum (talk | contribs) | RUVARO image upload |
You cannot overwrite this file.
File usage